Descargar Imprimir esta página

Cherubini META Dry Contact Switch 7 Instrucciones página 34

Relé un canal

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DEVICE CONTROL
Meta Dry Contact Switch 7 can turn ON and OFF the load by using an external switch,
or from remote through a controller.
Controlling the device by External Switches
For the operation of the device within the Z-Wave
connected to the device, control actions are performed on the external switches.
The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES
connected to the Line Signal terminal of the device which can be Clicks, Hold
Down and Up.
Event
Click
MultiClick=n click
Hold Down
Up
Since the device supports Central Scene Notification all the events described in the table
will be notified with a Central Scene Notification Report to the Lifeline. The events that
trigger a Central Scene Notification Report can be customized with the configuration
parameter in the Central Scene Notification Parameter section.
Type of switch
Momentary switch
(button)
Toggle Switch
(bistabile)
Momentary switch
Toggle Switch
Momentary switch
Momentary switch
34
network and controlling the loads
TM
Actions on the switch
Press briefly & Release
(when pressed it autonomously
returns to the initial position)
Press & Release
(a single click means one single
flip of the switch)
Sequence of consecutive n clicks
Press longer than click.
After a Hold Down always follows
an UP event.
Release.
The event applies only if there has
been a previous Hold Down event.

Publicidad

loading