Descargar Imprimir esta página

Cherubini META Dry Contact Switch 7 Instrucciones página 45

Relé un canal

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Parameter
Size
Number
45
1
Parameters Values
Value
Description
0
OFF
1-99
Specific diming value
100
ON
101
Propagate (output 1 status to the associated device)
102
Toggle remote (change status ON/OFF of associated devices)
Parameter
Size
Number
50
4
Parameters Values
Value
Description
0-3600
Specific time expressed in seconds.
Parameter
Size
Number
51
1
Parameters Values
Value
Description
1-99
Specify the minimum dimming value (not null)
Parameter
Default
Name
Value
G2_ASS_
101
VALUE
Parameter
Default
Name
Value
DIMMING_
5
TIME
Parameter
Default
Name
Value
MIN_DIM_
1
LEVEL
Description
The value used to control G2 association
group.
Min: 0
Description
Fade On/Off time in second used to con-
trol device in dimming group.
Min: 0
Description
Define the minimum dimming level to
control the device in a dimming group.
Min: 1
45
Max: 102
Max: 3600
Max: 99

Publicidad