Descargar Imprimir esta página

Cherubini META Dry Contact Switch 7 Instrucciones página 42

Relé un canal

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Timer management
It allows you to activate an ON and OFF timer independently. To activate the timers
you need to:
1) Define which event will start the timer (Parameter 30)
2) To set the Off timer define the time with parameter 31
3) To set the On timer define the time with parameter 32.
Parameter
Size
Number
30
1
Parameters Values
Value
Description
0
Disabled
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
Network (status change trigger by gateway or other devices in the
32
Z-Wave network).
64
System (based on the startup status, or other timer event).
If more than 1 event are supported, the value for the configuration parameter is the
sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 = 3
Default value: Disabled →0
Parameter
Size
Number
31
4
Parameters Values
Value
Description
0-360000 Specific time expressed in tenth of seconds for Status change.
Parameter
Default
Name
Value
TIMER_
0
SETUP
Parameter
Default
Name
Value
OFF_
0
TIMEOUT
Description
Define which trigger events activate the
timers when output status has changed.
Min: 0
Description
Time in tenth of seconds after which the
output will be switched Off.
Min: 0
42
Max: 127
Max: 360000

Publicidad

loading