Note: The extreme length of the drop down exhaust pipe is 1500mm; Shorten the length as much as
possible and keep it as level as possible during installation.
2. Adjust the air outlet slats manually and carefully to avoid damaging them.
3. Free access to the outlet pipe is important, installation errors will negatively affect the machine.
4. Make sure that the air in the outlet tube can circulate smoothly..
Tips:
The installation of the exhaust duct depends on the operating mode of the air conditioner. When the air
conditioner is in Auto and Cool mode, it is necessary to install the duct, but when the air conditioner is in
Fan or Dehu mode, it is not necessary to install the outlet duct. Users can compress or stretch the exhaust
duct according to usage preferences. Do not extend or bend the outlet duct arbitrarily.
- Install the drain hose in Dehumidifier (Dehu) mode.
In dehumidifier mode, a drain hose must be connected to the continuous drain
outlet at the top of the rear of the machine.
• Remove the rubber plug from the continuous drain outlet at the top of the rear
of the machine.
• Insert one end of the drain hose into the upper continuous drain outlet.
• Connec
t the other end of the drain hose to a drain or large capacity
container. You must take into account that the drain has to be lower than the
drain inlet.
- Install the drain hose into the lower tank.
• To prevent the lower tank from filling in very humid environments, a drain
hose must be connected to the continuous drain outlet on the underside of
the rear of the machine.
• Remove the rubber plug from the continuous drain outlet at the bottom of
the rear of the machine.
• Insert one end of the drain hose into the lower continuous drain outlet
• Connect the other end of the drain hose to a drain or large capacity
container. You must take into account that the drain has to be lower than the
drain inlet.