CONNECTIONS, OPERATING AND DISPLAY ELEMENTS
1
7
3
1
POWER IN
IP65 mains input socket with rubber sealing cap (TRUE1 compatible). Operating voltage 100 - 240
VAC / 50 - 60 Hz. Use the supplied power cable (when not in use, always close the rubber sealing
cap).
2
POWER OUT
IP65 mains output socket with rubber sealing cap (TRUE1 compatible). Enables power supply to
other CAMEO lights. Ensure that the total current consumption of all connected devices does not
exceed the value specified on the device in amperes (A) (when not in use, always close the rubber
sealing cap).
3
DMX IN
Male IP65 5-pin XLR socket for connecting a DMX control device (e.g. DMX console; when not in
use, always close the rubber sealing cap).
4
DMX OUT
Female IP65 5-pin XLR socket for forwarding the DMX control signal (when not in use, always
close the rubber sealing cap).
5
OLED DISPLAY
The OLED display shows the currently activated operating mode or the current DMX address
(main screen), the menu items in the menu and the numerical value or operational status of
certain menu items.
6
TOUCH-SENSITIVE CONTROLS
MENU – Press MENU to access the main menu. Press again or repeatedly to return to the main
screen.
UP and DOWN – Select menu items in the main menu (DMX address, operating mode, etc.) and in
the sub-menus using UP and DOWN. Change value or status of a menu item, e.g. DMX address. To
change a value quickly (e.g. the DMX start address), press and hold UP or DOWN.
12
5
6
2
8
4