7.7 Hob²Hood
It is an advanced automatic function which
connects the hob to a special hood. Both the
hob and the hood have an infrared signal
communicator. Speed of the fan is defined
automatically on basis of mode setting and
temperature of the hottest cookware on the
hob. You can also operate the fan from the
hob manually.
For most of the hoods the remote system
is originally deactivated. Activate it before
you use the function. For more
information refer to hood user manual.
Operating the function automatically
To operate the function automatically set the
automatic mode to H1 – H6. The hob is
originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes temperature of the cookware
automatically and adjusts the speed of the
fan.
Automatic modes
Automat‐
ic light
H0
Off
H1
On
3)
On
H2
H3
On
H4
On
H5
On
H6
On
1)
The hob detects the boiling process and activates
fan speed in accordance with automatic mode.
2)
The hob detects the frying process and activates fan
speed in accordance with automatic mode.
3)
This mode activates the fan and the light and does
not rely on the temperature.
Changing the automatic mode
1. Deactivate the hob.
Boiling 1)
Frying 2)
Off
Off
Off
Off
Fan speed
Fan speed
1
1
Off
Fan speed
1
Fan speed
Fan speed
1
1
Fan speed
Fan speed
1
2
Fan speed
Fan speed
2
3
2. Press
for 3 seconds. The display
comes on and goes off.
3. Press
for 3 seconds.
4. Press
a few times until H comes on.
5. Press
of the timer to select an
automatic mode.
To operate the hood directly on the hood
panel deactivate the automatic mode of
the function.
When you finish cooking and deactivate
the hob, the hood fan may still operate
for a certain period of time. After that time
the system deactivates the fan
automatically and prevents you from
accidental activation of the fan for the
next 30 seconds.
Operating the fan speed manually
You can also operate the function manually.
To do that press
This deactivates automatic operation of the
function and allows you to change the fan
speed manually. When you press
raise the fan speed by one. When you reach
an intensive level and press
set fan speed to 0 which deactivates the hood
fan. To start the fan again with fan speed 1
press
.
To activate automatic operation of the
function, deactivate the hob and activate
it again.
Activating the light
You can set the hob to activate the light
automatically whenever you activate the hob.
To do so set the automatic mode to H1 – H6.
The light on the hood deactivates 2
minutes after deactivating the hob.
when the hob is active.