Cautions
•
Single-use products are not designed to be reused. Reuse may cause a risk of cross-contamination, affect the measurement accuracy and/or system performance, or
cause a malfunction as a result of the product being physically damaged due to cleaning, disinfection, re-sterilization and/or reuse.
•
Verify that the sampling cannula, airway adapter, or sampling line is intact and undamaged.
•
For cannulas with an O
connector, verify oxygen flow prior to use.
2
•
Cleaning and sterilization will compromise system performance.
•
Remove sample cell from monitoring system when not in use.
•
Do not use on patients that cannot tolerate the removal of 50ml/min from their total minute ventilation.
•
Do not position cables or tubing in any manner that may cause entanglement or strangulation.
Accessory - LoFlo
CO
Sampling Cannula, Nasal (3468ADU-00, 3468PED-00, 3468INF-00)
2
CO
Sampling Cannula w/ Dehumidification Tubing, Nasal (3468ADH-00, 3468PEH-00, 3468INH-00)
2
CO
w/O
Cannula, Nasal (3469ADU-00, 3469PED-00, 3469INF-00)
2
2
CO
w/O
Cannula w/ Dehumidification Tubing, Nasal (3469ADH-00, 3469PEH-00, 3469INH-00)
2
2
CO
Sampling Cannula, Oral/Nasal (3470ADU-00, 3470PED-00)
2
CO
Sampling Cannula w/ Dehumidification Tubing, Oral/Nasal (3470ADH-00, 3470PEH-00)
2
CO
w/O
Cannula, Oral/Nasal (3471ADU-00, 3471PED-00)
2
2
CO
w/O
Cannula w/ Dehumidification Tubing, Oral/Nasal (3471ADH-00, 3471PEH-00)
2
2
Airway Adapter Kit, ETT >4.0mm, Deadspace <6ml (3472ADU-00)
Airway Adapter Kit w/ Dehumidification Tubing, ETT >4.0mm, Deadspace <6ml (3473ADU-00)
Airway Adapter Kit, ETT ≤4mm, Deadspace <1ml (3472INF-00)
Airway Adapter Kit w/ Dehumidification Tubing, ETT ≤4mm, Deadspace <1ml (3473INF-00)
Sampling Line Kit, Male Luer (3474-00)
Sampling Line Kit w/Dehumidification Tubing, Male Luer (3475-00)
Sample Line, Female Luer Connector (3476-00)
Disposal
Dispose of in accordance with all applicable federal, state, and local medical / hazardous waste practices.
Intended Use/Indications for Use:
For use with the LoFlo Sidestream CO
patients that are not intubated.
For use with the LoFlo Sidestream CO
patients with an endotracheal tube size larger than 4.0mm.
For use with the LoFlo Sidestream CO
patients with an endotracheal tube size of 4.0mm or smaller.
For use with the LoFlo CO
Sensor with ventilator and anaesthesia
2
circuits that have an integrated airway adapter with a female Luer-
Lok connector.
For adapting CapnoTrak accessories for use with a LoFlo Module.
Sensor when monitoring
2
Sensor when monitoring
2
Sensor when monitoring
2
5