Grounding installation
GB
This appliance is classified as protection class I and must be
connected to a protective ground. Grounding reduces the risk
of electric shock by providing an escape wire for the electric
current.
This appliance is fitted with a power cord with grounding plug
or electrical connections with grounding wire. The connections
must be properly installed and grounded.
Refrigeration circuit
(Fig.1 on page 3)
Symbol
Description
SA
Suction accumulator
EXV
Expansion valve
FT
Filter
CDN
Condenser
SP
Safety presostat
F
Fan
Preparation before use
• Remove all protective packaging and wrapping.
• Check that the device is in good condition and with all ac-
cessories. In case of incomplete or damaged delivery, please
contact the supplier immediately. In this case, do not use the
device.
• Clean the accessories and the appliance before use (See ==>
Cleaning & Maintenance).
• Make sure the appliance is completely dry.
• Place the appliance on a horizontal, stable and heat resistant
surface that is safe against water splashes.
• Keep the packaging if you intend to store your appliance in
the future.
• Keep the user manual for future reference.
NOTE! Due to manufacturing residues, the appliance may emit
a light odor during the first few uses. This is normal and does
not indicate any defect or hazard. Make sure the appliance is
well ventilated.
Operating instructions
Installation
• Use the flexible connection (length 1.3 m.) with the two filter
joints supplied with the appliance. We do not advise the use
of double water outlet with two stopcocks as they may close
the rear one by mistake, leaving the appliance without water.
Water pressure must be between 1 Bar and 6 Bar. If the pres-
sure exceeds these values, install the necessary corrective
components.
• It is important that the water line does not pass close to
sources of heat, and that the flexible hose or the filter does
not receive hot air from the appliance. It could cause de-
creasing of production.
• The drain must be below the appliance, by at least 150 mm.
• In order to prevent bad smells, install a siphon. The drainage
pipe should have an internal diameter of 30 mm and a mini-
mum slope of 3 cm per metre.
• The electronic board has a button battery for timer. During
8
Symbol
Description
EV
Evaporator
HGV
Hot gas valve
CM
Compressor
D
Drier
CDP
Condenser
presostat
installation, please remove the protection (board in the upper
side, behind the display - remove two screws under the upper
air grille, to access the electric box).
Start up
After installation (checking ventilation, conditions of the prem-
ises, temperature, water quality, etc.), proceed as follows:
For 270486, 270493:
• Open the water inlet. Check that there are no leaks.
• Open the door and remove the protection elements on the
curtain. Verify that the curtain moves freely.
• Connect the appliance to the mains.
• Push the button on the front of the appliance.
• Check that there is no part which is rubbing or vibrating.
• Close the door.
• Adjust the cycle time.
For 270516:
• Open the water inlet. Check that there are no leaks.
• Remove the two locking screws on top, take off the front pan-
el and remove protection elements on the shield and also on
the thickness sensor. Verify that the curtain and the thickness
sensor moves freely and check that the water tray is in place.
• Connect the appliance to the mains.
• Push the button on the back of the appliance and then set the
ice/wash switch to the position ice.
• Check that there is no part which is rubbing or vibrating.
• Replace the front panel in its place.
• Verify the ice slab with the fig. 2 on page 3. In case the thick-
ness sensor needs to be regulated, rotate the thickness ad-
justment screw clockwise to increase bridge thickness. Ro-
tate counter clockwise to decrease bridge thickness:
A: Too big
B: Proper size
C: Too smal
D: Thickness sensor
Control panel
• There is an ON / OFF button on the front of the appliance.
• To start the appliance,+ set the button to the ON (I) position.
• To turn off the appliance, set the button to the OFF (0) po-
sition.
Cleaning & maintenance
• ATTENTION! Always disconnect the appliance from the pow-
er supply and disconnect the water inlet or close the tap be-
fore storage, cleaning & maintenance.
• Do not use water jet or steam cleaner for cleaning and do not
push the appliance under the water as the parts will get wet
and electric shock might be resulted.
• If the appliance is not kept in a good state of cleanliness, this
can adversely affect the life of the appliance and result in a
dangerous situation.
• Checking and cleaning should be carried out at least every six
months. In very dusty places, it may be necessary to clean the
condenser in air-condensed appliances every month.
Cleaning (all models)
• Clean the exterior surface with a cloth or sponge slightly
dampened with a mild soap solution.
• Avoid water contacting the electrical components.