Descargar Imprimir esta página

Ferroli RIMINI DP Serie Instrucciones De Instalación, Uso Y Mantenimiento página 56

Ocultar thumbs Ver también para RIMINI DP Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

5. OPERATION
5.1. Control panel
The control panel is composed of a large TFT-LCD screen with white backlight and black
images for ease of legibility, and seven touch keys as outlined below:
Edit day, time and program
Selection of operating
mode
Forced or absence mode
Temperature, day, hour and
parameters selection
Keyboard lock
5.2. Turning the emitter on and off
To turn on the emitter, it has to be plugged into the power supply (230 V ~ 50 Hz), through its
plug; the standby symbol or the current operating mode will appear on the display. It is turned
off removing the plug from the socket.
If the emitter is in Standby mode, to set it to Operational touch and hold the Standby key;
a double beep will sound once the emitter is Operational. The screen lights up quickly, changing
from the standby screen to the previous operation mode.
From Operational, to set it to Standby, touch and hold the Standby key; a
long beep will sound, appearing the standby symbol on the screen (the
light fades after 1.5 seconds). When the emitter is in Standby mode, if you
touch any key the standby screen will appear for 10 seconds. From
Standby, the emitter can be locked (see section 5.9 of the manual).
In case of any power failure or disconnection the emitter will always remember the previous
mode of operation, the temperature, and the state (Standby/Operational and locked/unlocked).
If it is the first time that it is plugged in or has been disconnected for more than 4 days, it will be
necessary to edit the day and time according to section 5.5 of the manual. If the disconnection
has been for less than 4 days, the time and day of the week are saved.
Daily and weekly programs are never lost even when disconnected from power for long periods.
56
Exit Open Windows mode
EN
RIMINI DP
TFT-LCD Screen
EVANESCENT Function
Confirm day, time, program
and parameters
Copy the program
Standby key: switches the
emitter between Standby
and Operational
A73021554

Publicidad

loading