INSTALLATION INSTRUCTIONS ( CONTINUED )
Install Pump on Tank (model M-150S-EM & M-150S-E-PO)
1.
Clean the tank interior of all dirt and foreign material.
2.
Carefully lift pump / suction pipe assembly and insert suction pipe into the
tank opening.
Position the pump mount and tighten securely, making sure the threads are not
cross-threaded; the pump mount exterior threads are 2 inches NPT.
NOTE: To prevent pressure buildup and possible fuel leaks through the nozzle,
make sure the fuel tank is properly vented. A vent cap rated at 3 psi (6.90 kPa) or
less is recommended. Contact GPI for proper vent.
Install Hose and Nozzle
1.
Using pliers, remove the plastic plug from outlet port on front of pump. Wrap
one end of the dispensing hose with three to four turns of thread tape and
thread into outlet port (see Figure 8). Tighten securely using an adjustable
wrench.
2.
Wrap opposite end of hose with three or four turns of thread tape and thread
into nozzle. Tighten securely using an adjustable wrench (see Figure 9).
3.
Place the nozzle into the nozzle holder on the end of the pump motor
housing. Note that the nozzle cannot be placed in the holder unless the
pump switch is OFF (see Figure 10).
NOTE: For PO models, install supplied nozzle holder.
10
EN
Figure 8
Figure 10
Figure 9
Figure 11