en - Technical data
Vented system
Maximum nominal volume flow rate
Maximum permitted pressure loss
Connector on machine side (external diameter)
Connection pipe provided on site (internal diameter)
Maximum exhaust air temperature
As relative humidity inside the exhaust ducting can be as high as 100 %, suitable measures must be taken to prevent a backflow of con-
densate into the appliance.
Equipotential bonding
If local and national installation specifications require equipotential bonding, good galvanic contact must be guaranteed. Accessories for
equipotential bonding are not supplied and need to be ordered separately.
Installation dimensions
Casing width (without add-on components)
Casing height (without add-on components)
Casing depth (without add-on components)
Overall machine width
Overall machine height
Overall machine depth
Minimum width of transport opening
Minimum safety distance between wall and back of machine
Diameter of door opening
Door opening angle
Standard
Required anchor points
DIN 571 wood screw (diameter x length)
Rawl plugs (diameter x length)
Transport data, weight and floor load
Packaging width
Packaging height
Packaging depth
Gross volume
Gross weight*
Net weight*
Maximum floor load in operation*
*depending on equipment configuration
Emissions data
Workplace-related sound pressure level, washing
Sound power level, washing
Workplace-related sound pressure level, spinning
Sound power level, spinning
Average heat dissipation rate to installation room
Emission sound pressure level
46
320 m³/h
220 Pa
100 mm
100 mm
80 °C
692 mm
1940 mm
761 mm
692 mm
1942 mm
851 mm
800 mm
400 mm
370 mm
180°
4
12 mm x 90 mm
14 mm x 80 mm
2 x 750 mm
2 x 1214 mm
2 x 817 mm
2 x 744 l
232 kg
208 kg
3235 N
50 dB (A)
59,2 dB (A)
63 dB (A)
73 dB (A)
3,9 MJ/h
63 dB (A) re 20 µPa