TROUBLESHOOTING
PROBLEM
CAUSE
The battery pack is not attached to
the hedge trimmer.
No electrical contact between the
hedge trimmer and battery pack.
The battery pack charge is
depleted.
The battery pack is too hot. See
the chapter "Battery High-
temperature Protection".
The hedge trimmer is too hot. See
the chapter "Machine High-
temperature Protection".
Hedge trimmer
The hedge trimmer is used at low
doesn't work.
temperatures.
The lock-off lever and trigger
switch are not depressed
simultaneously.
The blade is jammed.
The battery pack has electronics
error. See the chapter "Battery
Electronics Error Protection".
Dry or corroded blades.
Blades or blade support is bent.
Excessive
vibration or
noise.
Bent or damaged teeth.
Loose bolts.
56 VOLT LITHIUM-ION CORDLESS ARTICULATING POLE HEDGE TRIMMER— HTX5300-PA
SOLUTION
Attach the battery pack to the hedge trimmer.
Remove battery pack, check contacts and reinstall
the battery pack.
Charge the battery pack.
Remove the battery pack and cool the battery pack
until the temperature drops below 67°C.
Remove the battery pack and cool the hedge
trimmer until the temperature drops below 80°C.
Place the battery pack and the machine at room
temperature (above 0°C) and charge the battery
pack fully. Contact EGO customer service center if
the machine still does not work.
Move the lock-off lever forward and press the
trigger switch at the same time.
Remove the battery pack from the machine, remove
the obstruction carefully, then reinsert the battery
pack and restart the machine.
Replace the battery pack or contact EGO customer
service center.
Lubricate the blades, following the instructions in
the "LUBRICATING THE BLADES" section in this
manual.
Replace with a new blade or support. Contact EGO
service center for blade or support replacement.
Replace with a new blade. Contact EGO service
center for blade replacement service.
Check all loose bolts. Use an adjustable wrench and
the included hex wrench to tighten the loose bolts.