ENGLISH
1) INSTALLATION INSTRUCTIONS
2) P1000 XL CATC Flush cock ND20 - G3/4" EN 12541 compliant
3) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain
the pipes which can damage the mechanisms or water passages (PRESTO® heads that can be dismantled from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
4) Part no. 14221 - P1000 XL Flush tapware Class I
Part no. 14220 - P1000 XL Flush tapware Class II
Part no. 18925 - CATC for partition of 0.1 to 1.5 cm
Part no. 18926 - CATC for partition of 1.5 to 20 cm
Part no. 18927 - CATC for partition of 20 to 30 cm
- For partition > than 30 cm: contact us
(Note: The flush cocks must be equipped with an individual shut-off valve)
Technical data:
- Male feed G3/4"
- 1/4 turn stop cock
- Automatic flow limiter.
- Adjustable supply volume: 6 to 9l. (Supplied set to 6l)
- Remote control by priming pump with 0.75m of flexible tube Ø4
- Outlet connector for 28x1.5Ø PVC tube (part no. 47850 ).
5) Shut-off valve
6) Flush tube height 500mm minimum
7) In order to benefit from the acoustic grading of P1000XL, never use the shut-off valve for flow regulation. It
must be mostly kept open
8) Flush tube Part no. 47850 not supplied
9) Installation
10) Bleed the installation before installing the valve
11) As per inflow arrow
12) Tube A – Ø4 Lg: 0.75m
13) Green tube A connection
14) Tube B – Ø4 Lg: 0.75m
15) As per outflow arrow
16) 1- Install the tube A according to the diagram; 2- Install tube B
17) CATC assembly (See instructions for the wall-mounting assembly)
18) Thickness of the wall (E)
19) 8mm clearance adjustment of the cylinder
20) Adjusting the supply volume (P min.: 1.2 bars); (P max.: 4 bars)
21) Volume (litres)
22) Number of turns
23) Volume
24) Flow rate (l/s)
25) Flow curve
26) Pressure (bar)
27) In the event of an anomaly, remove the timer cartridge and rinse in clean water
28) Dismantling the valve
29) Spares bags for P1000 XL Class II - Timer cartridge - Part no. 01270
30) P1000 XL TC discharge Part no. 90930
31) Replacing the cartridge
32) Cartridge + seals Part no. 01270
33) Foolproof location of the cartridge in the body
34) For the adjustment of the volume see chapter "Adjustment of the supply volume"
35) Foolproof location of the seal in the cartridge
36) This document is not contractual; we reserve the right to modify the characteristics of our products without notice.
37) PATENTED and REGISTERED MODELS
- Hydraulic discharge P1000 XL TC – Part no. 90930