MODELLI
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE
(Silicone)
L= Smooth hotplate R= Corrugated hotplate
L/R= ½ Smooth +1/2 Corrugated
S= Chromium-plated hotplate
The data plate is on the front panel (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, in force.
The appliance is supplied without the electric connection cable. To install the power supply cable, proceed as follows:
•
Disconnect the power supply.
•
Remove the rear panel
•
Push the connection cable through the cable blocked, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
•
Block the cable with the cable blocked, and reassemble the front panel. The earth wire must be longer than the
others so that if the cable blocked should break, it will disconnect after the tension wires.
N.B. The connection cable must have the following characteristics: it must be at least the silicone type (resistant to a
temperature of at least 180°C, and must have an adequate section for the power of the appliance (see technical data
table).
The appliance must be connected to an equipotential system. The connection screw is positioned at the back of the
appliance and is identified by the
GB
TECHNICAL DATA TABLE
FT*-94ET*
40x90x90
400V 3N 50Hz 400V 3N 50Hz
8,7
6
5x1 mm²
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
EQUIPOTENTIAL
symbol.
IE
FT**-98ET*
FTC-94ET
80x90x90
40x90x90
400V 3N
50Hz
17,39
5,1
12
3,5
5x2,5 mm²
5x1 mm²
20
FTC-98ET
80x90x90
400V 3N
50Hz
10,2
7
5x1,5 mm²