Function Priority

Simulated Land Line Priority

If the device connected to the LI terminals (e.g. Control panel) tries to engage the line, the BGSM-I will interrupt any ongoing
communications (SMS or ContactID) in order to send the calls generated by the device. The BGSM-I will restart the
interrupted communications when the device disengages the line.

SMS or Contact ID Priority

If the device connected to the LI terminals (e.g. Control panel) is using the GSM Network (through the BGSM-I Interface) when
an SMS or ContactID associated event occurs, the BGSM-I will interrupt the ongoing call and send the respective SMS
message or ContactID report.

ContactID Event Priority

If several events occur contemporarily, the respective messages will be sent in chronological order. If an event is associated
with a ContactID report and an SMS communication, priority will be given to the ContactID report.

ACTIVATING THE OUTPUTS

The BGSM-I has 4 OC outputs programmable as Automatic (outputs with this attribute will activate in response to the
associated events) or Remote Control (outputs with this attribute can be activated manually from remote locations by
means of SMS messages or calls from enabled telephone numbers.

Activating/Deactivating Automatic Outputs

The OC outputs can be activated automatically by the following events:
 Land line trouble (line down)
 GSM Module trouble
 GSM trouble (Limited/No Service)
 Power supply trouble
 Incoming call
 Outgoing call
 ContactID digital report
 Enablement of remote programming
, , , , , Once an OC output has been activated automatically, it will not restore to standby until all the causes of
activation clear.

Activating/Deactivating Remote-control Outputs

The OC outputs can be programmed as BISTABLE (activated/deactivated by means of an SMS text message or Remote
Control number) or MONOSTABLE (activated by means of SMS text messages or Remote Control numbers). Once
a Monostable output has been activated, it will not deactivate until the programmed ON Time expires. Each output can be
set up to provide a feedback signal (ring or SMS text message).
, , , , , For further information regarding the terms "Access Code" and "Output Label" (used in the following
section), refer to the "Outputs Page" in the "Software" section.

Bistable Outputs (for appliance management)

Bistable OC outputs can be activated in 2 ways.
1. By sending a case sensitive SMS text message containing the respective Access Code, placed between pound signs
(#), and the Output Label (e.g. GATE) followed by =ON, as follows:
#ACCESSCODE#OUTPUTLABEL=ON
2. By sending a cost-free call from a preset Remote Control number. The BGSM-I will activate the respective output
without answering the call.
Š
(example: #AZ55#GATE=ON)
G
G
G
G
G
19