Outputs Page; Output Settings; Access Code; Contact Id Page - Bentel Security BGSM-I Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Outputs Page

This page will allow you to set up and control the outputs.

Output Settings

† Polarity: select the polarity of the output: H-Normally Open L-Normally Closed.
† For Land Line Trouble, GSM Trouble, etc.: select the events that will activate the outputs.
† Reserved Output: If this option is selected, all other events assigned to the output in this section will be ignored. Select
this option, if the output concerned is to be used for Remote control purposes (refer to "Activating and Deactivating and
Remote Control Outputs").
The following options will affect Reserved Outputs ONLY.
† Output Label - Type in the label (max. 8 characters) of the appliance (e.g. Gate) which is to be remote-controlled
via SMS.
† Output feedback - Select the type of feedback signal (None, Ring or SMS) to be sent when the respective output
activates. If the Output Label field is empty, the SMS option will not be available.
† Monostab. - Under normal circumstances, these outputs hold active status until they receive a deactivation
command. If automatic deactivation is required, it will be necessary to program the ON Time (i.e. the time the output
will hold active status).
† ON Time (sec.) - Enter the required ON Time in seconds (accepted values 2 to 254 seconds). If the output has been
programmed as Monostable, this value will determine the amount of time the output will hold active status before
restoring to standby.

Access Code

Type in the code (maximum 4 alphanumeric characters) which will allow the user to control the outputs over-the-phone.

Contact ID Page

This page will allow you to set up the Contact ID function.

Telephone numbers to call

Four telephone numbers of up to 20 digits (digits and + signs).
The BGSM-I will try each telephone number 3 times before considering a call unsuccessful and quitting.
, , , , , The Contact ID Codes will be sent to the first number (with Contact ID reporting protocol) that answers the
call.

Events description

† Customer Code - type in a 4 character code (accepted values: digits and the letters A, B, C, D, E and F).
† Event Code - type in the Contact ID to be transmitted when the respective event occurs.
† Send - select (tick) the events to be sent.

Periodic Reports

The BGSM-I can be programmed to send Periodic Contact ID reports. This section will allow you to select the Date and Time
of the first periodic report and the Interval between reports.

Calls Page

This page will allow you to view on the screen the Dialled, Received and Missed calls.
, , , , , Each section can store a maximum of 10 calls. If the number of calls exceeds this limit, the BGSM-I will make
space automatically by deleting the oldest calls.

Load button

To view the Dialled, Received and Missed calls, click the Load button. Depending on programming, some telephone
numbers may not have Caller ID.
Š
G
G
G
G
G
23

Publicidad

Tabla de contenido
loading

Tabla de contenido