For appliances installed in banks, an optional kit is
available with the supporting frame and some trims.
ELECTRICAL CONNECTION
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400V/3~ (see attached wiring diagrams).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker (A)
with overload cutout and differential safety
breaker close to the appliance.
2 - Open the hatch (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Undo the screws (E) to remove the guard (F).
5 - Connect the circuit-breaker (A) to the terminal
boards (G) of the appliance as shown in the di-
agram and in the electrical system diagram at
the back of the manual. Use a cable with at
least H05RN-F characteristics.
Important
When connecting, take care to connect the
earth line correctly
6 - Fix the cable with the screws (H).
7 - Replace the control panel (D) on completion of
the operation.
B
B
A
08WVT2IV
H
- 17 -
IDM-39610801100.tif
C
E
IDM-39613201000.tif
04WVT1-2IV / 08WVT1I
H
G
D
IT
GB
F
DE
FR
ES
G
English