Adjustment
1
Program the travel
Without a properly installed safety reversal
system, persons (particularly small children)
could be SERIOUSLY INJURED or KILLED by a
closing garage door.
• Incorrect adjustment of garage door travel
limits will interfere with proper operation
of safety reversal system.
• After ANY adjustments are made, the
safety reversal system MUST be tested.
Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid flat) on
floor
While programming the travel, the UP and
DOWN buttons can be used to move the door
as needed. The Safety Reversing Sensors
will be disconnected during the Program the
Travel process. During the Automatic Force
Setup the door will automatically open and
close.
1.4 Press and hold the DOWN button
until the door is in the desired DOWN
position.
1.1 Press and hold the Adjustment Button
until the UP Button begins to flash and/
or a beep is heard.
The Safety Reversing Sensors will be
disconnected during the Program the Travel
process.
1.5 Once the door is in the desired DOWN
position press and release the Adjustment
Button. The garage door opener lights will
flash twice. Program the Travel is now
complete. If the garage door opener lights
flash 5 times, then programming has timed
out and the Travel Limits have not been set.
Please restart the Program the Travel process.
1.6
Add the Step Saver sticker under the yellow
program button.
1.2 Press and hold the UP Button until the
door is in the desired UP position.
2
Automatic Force Set Up
Once both the up and down positions have been manually set, the Safety Reversing Sensors
will reconnect and become operational. Then, the opener will enter a force-sensing operation by
automatically moving the door open and close. The garage door opener will sound an audible and
visual alert before automatically opening and closing the door. The garage door opener will beep
three times, confirming that the Automatic Force Setup completed successfully. Adjustment is
complete.
If you hear one long beep after the door attempts to move, then the Automatic Force Set Up has
not completed successfully. Please start over at step 1 of Program the Travel..
3
1.3 Once the door is in the desired
UP position press and release the
Adjustment Button. The garage door
opener lights will flash twice and the
DOWN Button will begin to flash.