Magnetrol ECLIPSE 706GWR Manual De Operación E Instalación página 36

Transmisor de nivel de radar de onda guiada de alto desempeño, 4ta generación
Ocultar thumbs Ver también para ECLIPSE 706GWR:
Tabla de contenido

Publicidad

2.6.5 Menú de Configuración del Modelo 706 — Ajustes de Dispositivo
Home Screen
Main Menu
Device Setup
Quick Start
Identity
Basic Config
I/O Config
Display Config
Advanced Config
Factory Config
36
Sensitivity:
0 to 100 echo strength units
Blocking Distance:
-7.5 to +100 feet
(-2 m to 30 m)
Safety Zone Alarm:
None
3.6 mA
22 mA
Latched 3.6 mA
Latched 22 mA
Safety Zone Height:
(not used when Safety Alarm is
None)
2 inches to 100 feet
(5 cm to 30 m)
Reset SZ Alarm
(used when Safety Alarm is Latch
3.6 mA or Latch 22 mA)
Failure Alarm Delay:
0 to 5 seconds
Level Trim:
-2.00 to + 2.00 feet
(-0.6 m to + 0.6 m)
THRESHOLD SETTINGS
Lvl Thresh Mode:
Auto Largest
(not used with Interface and Level)
Fixed Value
Auto Upper
Sloped
Sloped Start Value:
(When Lvl Thresh Mode is Sloped)
Lvl Thresh Value:
0 to 100 echo strength units
Sloped Start Value
(used when Lvl Thresh Mode is
Sloped)
0 to 100 echo strength units
Sloped End Dist:
(used when Lvl Thresh Mode is
Sloped)
25 to 100 feet
(7 to 30 m)
57-606 Transmisor de Radar de Onda Guiada ECLIPSE Modelo 706
Ifc Lvl Thresh Mode:
(Interface and Level only)
Auto Largest
Fixed Value
Ifc Lvl Thresh Value:
(Interface and Level only)
0 to 100 echo strength units
EoP Thresh Mode:
Auto Largest
Fixed Value
EoP Thresh Value:
0 to 100 echo strength units
ENDofPROBE ANALYSIS:
EoP Polarity:
Positive
Negative
EoP Analysis:
(not used with Interface and Level)
Off
On
EoP Dielectric:
(not used with Interface and Level)
1.20 to 9.99
ECHO REJECTION:
View Echo Curve
REJECTION CONTROL:
Reject Curve State:
Off
Disabled
[Enabled]
Reject Curve Mode:
Level
Distance
Saved Medium
NEW REJECT CURVE:
Actual Medium
Save Reject Curve
Compensation:
None
Auto
Manual
Vapor Dielectric
1.00 to 2.00
HF Cable Length:
Integral
3 feet
12 feet
Buildup Detection:
Off
On
ANALOG OUTPUT:
HART Poll Address:
0 to 63
Analog Output Mode:
Disabled (Fixed)
Enabled (PV)
[Fixed Current Value]
4 to 20 mA
ADJUST ANALOG
OUTPUT:
Adjust 4mA
Adjust 20mA
New User Password:
0 to 59,999
CONFIG CHANGED:
Indicator Mode:
Disabled
Enabled
Reset Config Chngd:
Reset?
No
Yes
Reset Parameters:
No
Yes