baltur BT 75 DSPN Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Control box
Safety Time
& relative
in seconds
Programmer
LAL 1.25
5
Cyclic relay
DIAGRAM OF FUEL OIL MODULATING BURNERS (MAGNET - NOZZLE WITHOUT PIN)
CONNECTION AT THE FUEL FEEDING
DIAGRAM FOR ONE OR MORE BURN-
ERS (SEE 0002901120; 8511/6; 8513/7)
1
FILTER
2
BURNER PUMP (20÷22 bar)
3
PRESSURE GAUGE (0÷40 bar)
4
ATOMIZER UNIT
5
RETURN NOZZLE WITHOUT PIN
6
ROD WITH CLOSING PINS
7
BY-PASS HOLES
8
CLOUSING SPRING
9
OPENING ELECTROMAGNET
10 RETURN PRESSURE REGULATOR
MIN = 10÷12 bar / MAX = 18÷20 bar
11 MODULATION SERVOMOTOR
12 CONTROL DISK FOR VARIATION OF FUEL / AIR DELIERY
Control box specifications
Pre-Ventilation & Oil
Pre-ignition Time
Pre-circulation Time
in seconds
in seconds
22,5
13 AIR REGULATION SHUTTERS
14 FLEXIBLE PIPE
11 MODULATION SERVOMOTOR
12 CONTROL DISK FOR VARIATION OF FUEL / AIR DELIERY
13 AIR REGULATION SHUTTERS
14 FLEXIBLE PIPE
15 ELECTRIC PRE-HEATER
16 SELF-CLEANING 0.3 mm FILTER
17 THERMOMETER
18 MIN. PRE-HEATER THERMOSTAT
19 MAX. PRE-HEATER THERMOSTAT
20 PRE-HEATER ADJUSTER THERMOSTAT
21 NOZZLE RETURN THERMOSTAT
14 / 31
98321_2010/03
Post-ignition
Time
in seconds
2,5
5
E
Time between
N
1st flame & Start
of Modulation
G
in seconds
L
20
I
S
H

Publicidad

Tabla de contenido
loading

Tabla de contenido