120 V, 20 Ampere
Duplex
Receptacle
20 amps of current
may be drawn
from each half of the
receptacle.
However,
total power
drawn
must be kept within
nameplate
ratings.
These receptacles
may be used along with the
twistlock
receptacle
provided
the generator
is not overloaded.
C.
120 Volt GFCI
Receptacle
Ground
Fault Circuit
Interrupter
duplex receptacle
is rated so
that a total of 20 amps may be drawn
regardless
of whether
both
halves or just one receptacle
is used.
This receptacle
may be used
along with other receptacles
provided
the generator
is not overloaded
and total power
drawn
is kept within
nameplate
ratings.
Ground
Fault Circuit
Interrupter
(Conforms
to U.L 943, Class A and NEC requirements)
This device
protects
you against
hazardous
electrical
shock
that may
be caused
if your body becomes
a path through
which
electricity
travels
to reach ground.
This could
happen
when you touch an
appliance
or cord that is " live " through
faulty mechanism,
damp or
worn insulation,
etc.
D.
120/240
V, 30 Ampere
Twistlock
Receptacle
A maximum
of 30 amps may be drawn
from the 120/240
volt
receptacle,
provided
it is the only receptacle
used.
However,
current
must be limited
to the nameplate
rating.
If the 120/240 volt
receptacle
is used along
with the 120 volt receptacle,
the total load
drawn
must not exceed
the nameplate
ratings.
E.
Circuit
Breakers
The receptacles
are protected
by an AC circuit
breaker.
If the
generator
is overloaded
or an external
short circuit occurs,
the circuit
breaker
will trip.
If this occurs,
disconnect
all electrical
loads and try
to determine
the cause
of the problem
before
attempting
to use the
generator
again.
If overloading
causes
the circuit
breaker
to trip,
reduce the load. NOTE:
Continuous
tripping
of the circuit
breaker
may cause damage
to generator
or equipment.
The
circuit breaker
may be reset by pushing
the button of the breaker.
F.
Panel Light
The panel light comes
on automatically
when the engine is
started.
The light goes off automatically
when the engine is shut off.
G.
DIGITECH
TM
DigitalInformation
Center
The DIGITECH
TM
Digital
Information
Center is a patented
feature
available
only on select Coleman_,R) Powermate_,R) Brand
generators.
At a glance,
the user can instantly
see how much of the
generator's
output
capacity
is being
used and how much power
remains
available.
The display
also indicates
the time since last user
reset and the total accumulated
runtime
of the generator.
Power
Bar - This bargraph
provides
a quick
visual indication
of
the percentage
of rated output
currently
being
supplied.
% Load
Indicator
- This is a numeric
version
of the Power Bar.
Hour
Meter
- This indicates
the total number
of hours
the
generator
has run since manufacture.
Maintenance
Timer
- This indicates
the number
of hours
the
generator
has run since the last user reset. This timer should be reset
after evm 7 oil change
or any other maintenance
task. Follow
the
instructions
in the engine owners
manual
for proper
engine
maintenance
intervals.
Reset
Button
- Pressing
and holding
this button will reset the
Maintenance
Timer to 0 HRS.
H.
Fuel Shut-Off
I.
Engine
On/Off
Switch
J.
Engine
Choke
Lever
K.
Yamaha
10HP OHV
Engine
with:
Cast-Iron
Cylinder
Sleeve
Low Oil Sensor
L.
7 Gallon
Plastic
Fuel Tank
M.
Fuel
Gauge
N.
Generator
Head
O.
Storage
Bin
E
Oil Drain
Q.
Pneumatic
Tires
R.
Retractable
Handles
S.
Handle
Release
Buttons
To extend the handles,
press
the handle release
buttons
on the
wheel end of the unit. Pull the handles out until the handle release
buttons lock in place on the engine end of the unit.
To retract the handles, press the handle release buttons on the
engine end of the unit. Push the handles in until the
handle release buttons lock in place on the wheel end of the unit.
www.powermate.com
9
Customer Hottine 1-800-445-1805

Publicidad

loading