Descargar Imprimir esta página

Klarstein SHIRAZ PREMIUM SMART Manual Del Usuario página 36

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
Stability of the display
In the Celsius state: When the temperature measured by the temperature probe
is within ± 1 ° C of the set temperature, the temperature display shows the set
temperature value.
In Fahrenheit state: if the temperature measured by the temperature probe is
within ± 2 °F of the set temperature, the temperature display will show the set
temperature value.
Error Codes
Error Code LL: When the temperature measured by the temperature probe is
below 0 degrees Celsius, „LL" is displayed flashing and cooling is stopped.
If the temperature probe is shorted or disconnected, the set temperature value is
displayed, the compressor operates for 15 minutes and stops after 18 minutes
When the temperature measured by the temperature sensor is higher than 37
degrees Celsius, the set temperature value is displayed, the compressor operates
for 15 minutes and stops after 18 minutes.
WLAN function
The decimal point at the bottom right of the numeric display on the screen (see
figure below) indicates that the WLAN function is active.
When the unit is turned on, the WLAN indicator flashes, indicating that the WLAN
connection can be established.
Resetting the WLAN function
If the WLAN indicator is NOT flashing when the power is turned on, the WLAN
connection CANNOT be established. Press the Set key and the Down key
simultaneously for 3 seconds, and the decimal point (WLAN status indicator) will
flash at the bottom right of the digital screen. The screen changes to the WLAN
connection mode and the WLAN connection can be established.
36

Publicidad

loading

Este manual también es adecuado para:

100453371004533810045339