Descargar Imprimir esta página

Erreka KM-400S Manual De Instrucciones página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

START-UP
- Before connecting the circuit board to the mains, connect the various peripherals to the circuit board.
Important: Remember to connect the earth cable.
1. Connect the circuit board to the mains (general ON-OFF switch).
2. Align the turn directions of the motor with the end stops.
- Activate the DIP 9 of the selector (G) in accord with the position of the motor on the gate.
- Gate Closed Open - Open Gate Close. Use the pushbuttons (J) Pul 1-Close and Pul 2-Open to check that the turn directions
of the motor are correct. If they do not coincide, swap over the terminal cables 13 and 14.
- Check that the ends of sweep (D and I) are connected correctly.
3. Adjust the power of the motor
- Set the par H potentiometer to minimum (turn it anticlockwise). Turn it gradually clockwise until the motor has enough power
to move the gate along the entire sweep.
4.- Opciones del selector (G).
DIP 1-ON
Enables programming.
DIP 2-ON
Memorises the sweep of all the gate.
DIP 1-ON
Enables programming.
DIP 3-ON
Memorises the sweep of the pedestrian opening.
DIP 1-ON
Enables programming.
DIP 4-ON
Records total opening code/chanel.
DIP 1-ON
Enables programming.
DIP 6-ON
Records pedestrian opening code/chanel.
DIP 2-ON
DIP 3-ON
DIP 3-OFF
DIP 4-ON
DIP 4-OFF
27
Activates the 3 sec. flashing
light warning.
Step-by-step function.
Community function.
Automatic cycle.
Semi-automatic cycle.

Publicidad

loading