DIP 5-ON
Optional automatic.
DIP 5-OFF
NO Optional automatic.
DIP 6-ON
Flashing light output.
DIP 6-OFF
Flashing light on (not flashing) output.
DIP 7-ON
Encoder enabled.
DIP 7-OFF
Encoder disabled. Eliminating the encoder
is the same as eliminating the internal
safety of the motor.
5.- Automatism programming:
5.1.- Recording door travel.
-Move the door to closed position, either manually or using the control panel buttons.
-Turn DIP 7 and DIP 8 to ON (Gentle stop and encoder options activated).
-Turn DIP 1 to ON. (Check LED DL3 comes on).
-Turn DIP 2 to ON.
-Press Start (Button C). The door will begin to open.
-Press Start (Button C) when the door is moving, at the point where you want the door to start slowing down
(50 cm from the end of its run). The door will then be stopped by the limit switch (door open).
-Press Start (Button C) for the door to start closing.
-Press Start (Button C) when the door is moving, at the point where you want the door to start slowing down
(50 cm from the end of its run). The door will then be stopped by the limit switch (door closed).
-Turn DIP 1 to OFF.
-Turn DIP 2 to OFF.
5.2.- Recording of partial opening (pedestrian)
Turn DIP 1 to ON.
-
Turn DIP 3 to ON.
-
Press "Peatonal". The gate starts to open.
-
Press "Peatonal" and at the position where we want it to start slowing down.
-
Press "Peatonal" to close the door in needed position of pedestrian opening.
-
Press "Peatonal" for the gate to begin to close.
-
Press "Peatonal" when the gate is in movement and at the position where we want it to start slowing down.
-
The gate then stops at the end of sweep.
Turn DIP 1 on the selector to OFF.
-
Turn DIP 3 on the selector to OFF.
-
N.B. For all types of operation:
• If during the opening manoeuvre, the gate comes up against an obstacle, it will stop and close for 2 seconds.
• If, during the closing manoeuvre, the gate comes up against an obstacle, it stops and returns back to the open position.
• Whenever the button is pressed while the gate is closing, it stops and returns to open position.
DIP 8-ON
Slow down activated.
DIP 8-OFF
Slow down deactivated.
DIP9-ON/OFF
Change the position of the ends of sweep
(open instead of close and vice versa).
DIP10-ON
Set always this DIP in ON