TROUBLESHOOTING
1. The motor does not work:
1.1. Check that the installation is correctly connected (Fig. 2)
1.2. Check that voltage is reaching the motor. (230V AC)
2. The motor works in one direction only:
2.1 Check if the motor common is correctly connected (Fig. 2)
2.2 Check that the condenser is connected.
3. The motor has no power:
3.1. Unlock the motor and check if the gate has any excessive resistance in its sweep. If so, remove the motor and clear the
resistance until the gate moves easily and freely when pushed.
3.2. Check that the condenser is connected and that it has the correct capacity (see label on motor).
3.3. Check if the motor is locked. If not, lock it.
4. The gate does not reach the end of sweep:
Check if the opening and closing times are in accord with the length of the gate.
If the fault persists after you have made all the checks and adjustments, go to your nearest distributor or ERREKA
technical service with as many details as possible about the fault.
INSTALLING THE MECHANISM
The M-400S model is compliant with the European reference directive:
Machinery Directive 89/392/CEE.
Low Voltage Standard 73/233/CEE
Electromagnetic Compatibility 89/336/CEE
It is recommended that the mechanism be installed by professionally qualified personnel in compliance with the legal standard
corresponding to each place of installation.
CERTIFICATE OF WARRANTY
Automatismos Erreka guarantees this apparatus for a period of 12 months from the supply date.
Said warranty is applicable to any fault in manufacture.
The installer is responsible for taking the appliance to authorised technical service centres.
This warranty does not include:
.- Damage caused by incorrect installation or use of the apparatus.
.- Damage resulting from handling by non-authorised personnel.
.- Damage caused by external or atmospheric agents (lightning, floods, etc.).
32