Descargar Imprimir esta página

Accessmatic Scorpion 1800 Manual De Instalación página 32

Publicidad

Idiomas disponibles

Idiomas disponibles

6.6 Photobeam
p1
p3
H0
H1
H0
6.7 Auto close ON/OFF
p1
p4
b0
b9
b0
6.6.1 Press and hold SET, it displays "P1".
6.2.2 Press UP twice, it displays "P3".
6.3.3 Press SET to show current situation. Press UP once it
displays "H1", the photobeam is enabled. Press down once, it
displays "H0", the photobeam is disabled. Press SET to con rm
and quit.
6.6.4 If you do not use photobeam device, please make sure
it displays "H0", to close this function.
6.7.1 Press and hold SET, it displays "P1".
6.7.2 Press UP three times, it displays "P4".
6.7.3 Press SET to show current situation, Press UP to increase the
auto – close one minute or press DOWN to decrease one minute.
Maximum degree in "b9", minimum is "b0". Press SET to con rm.
6.7.4 The default setting is "b0", "b0" shows auto – close o .
This function works when the door reaches the open position.
8
Code: SC1800

Publicidad

loading

Este manual también es adecuado para:

Sc1800