7.2 Garden Function
p1
p9
d1
d2
d0
7.3 Set ventilation position (or pedestrian position)
p1
pA
r0
r9
r0
7.2.1 Press and hold SET, it displays "P1".
7.2.2 Press UP eight times, it displays "P9", press SET to show the
current situation.
7.2.3 Press the UP key twice. It displays "d2". Indicates that the
garden function is open, when the remote control is pressed during
the door opening process, the door will stop, when the control
signal is received again, the door will be opened again until it
reaches the top, when a signal is received during the door is closed,
the door will be opening immediately.
7.2.4 Press the UP key twice. It displays "d2". Indicates that the
garden function is open, when the remote control is pressed
during the door opening process, the door will not be
controlled by the signal and open to the top, when a signal is
received during the door is closed, the door will be opened
at once.
7.2.5 Press de DOWN key once, it displays "d0", shows that the
garden function is closed. After the setting is completed, press the
SET key to con rm. Default values is "d0".
7.3.1 Press and hold SET, it displays "P1".
7.3.2 Press UP nine times, it displays "PA", press SET to show
current situation.
7.3.3 Press the UP or DOWN to adjust the setting. The display "r0"
means that the ventilation function is o ; the display "r1" to "r9"
means that the ventilation position is the set value (1 - 9) x 2cm;
press the "P" key to save and return to stand by state.
7.3.4 Default s4etting: "r0"
11