Prerequisite
–
Pipe ends are deburred and clean.
–
The pipe section and pressfitting are
fitted together according to the
installation manual of the piping
system.
–
The pressing attachment is inserted
correctly.
1
In order to activate the tool from idle
state, tap the start button.
✓ The tool is ready for operation;
the green LED lights up.
2
Fit the pressing attachment to the
pressfitting correctly and do not tilt.
→ See user manual for the Geberit
pressing attachments in question
90071994442300555 © 12-2023
968.361.00.0(03)
CAUTION
Danger of crushing
▶ Keep hands away from the
pressing attachment.
3
Press the start button for at least 2
seconds.
✓ The pressing procedure
proceeds automatically after a
force is detected, and the green
LED switches off.
Result
✓ After the pressing operation has been
completed, the roller drive returns to its
starting position. The green LED lights
up and the pressing tool is ready for
operation again.
Cancelling the pressing
procedure
▶
Press and hold release button.
Result
✓ The roller drive in the pressing tool
returns to its starting position. The
pressing procedure must be repeated
for a complete press connection. The
pressing attachment must not be
removed or rotated at this time.
EN
29