Seal the wall and floor openings
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed. See
Figures A, B, C and D on pages 4 and 5.
Connect the range to the gas supply
Before connecting gas supply to range, review the
suggested power source location drawings (See Figures
A, B, and C on page 4). To prevent leaks apply pipe joint
sealant on all male (outside) pipe threading. The Pressure
Regulator can be found mounted to the lower left rear of
range (See Fig 32). To install the gas supply:
1.)
Install 1/2" NPT 90° Black Pipe Elbow to the gas supply
pipe stub (See Fig 33)
2.)
Install an external gas Shut-Off Valve (manual) to gas
supply line in an easily-accessible location outside of the
range. Be sure you know how and where to shut-off the
gas supply to the range (See Fig 33).
3.)
Install
Flare
Adapter*
to gas
Pressure
Regulator
(See Fig. 33).
Pressure
Regulator
Location and
Installation
of
Gas
Supply
Flexible Appliance
Conduit
Flare
Manual
1/0" NPT
Pressure
_--, Adaptor Shutoff Black Pipe
Regulator
|
Valve
90° Elbow
Flare
'
{
Adaptor
ave
Fig. 33
ONT NOWTe ST Do not allow the Pressure Regulator to turn
on pipe when tightening fittings.
4.)
Attach flexible Appliance Conduit to Flare Adapter on
Pressure Regulator (See Fig 33).
Install 2nd Flare Adapter* to external manual Shut-Off
Valve (See Fig 33).
6.) Attach flexible Appliance Conduit to Flare Adapter on
Shut-Off Valve (See Fig 33).
7.) After making these connections,
check for gas leaks.
Turn the gas supply on to the range and use a liquid leak
detector at all joints and conduits to check for leaks in
the system.
5.)
10
*NOTE: Be sure to use the 2 Flare Adapters supplied with
the Flexible Conduit Kit.
PNUTEGTIIE! Do not use a flame to check for gas leaks.
Checking Manifold Gas Pressure:
Disconnect the range and its individual shut-off valve from
the gas supply piping system during any pressure testing
of that system at test pressures greater than 14" of water
column pressure (approximately 1/2" psig). The appliance
must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 14" of water column
pressure (approximately 1/2" psig).
If it should be necessary to check the manifold gas
pressure, connect manometer (water gauge) or other
pressure device to the top burner right rear orifice.
Using
a rubber hose with inside diameter of approximately 1/4,"
hold tubing down tight over orifice.
Turn burner valve
on.
For an accurate pressure check have at least two
(2) other top burners burning. Be sure the gas supply
(inlet) pressure is at least one inch above specified range
manifold pressure. The gas supply pressure should never
be over 14" water column. When properly adjusted for
Natural Gas the manifold pressure is 4" (For LP/Propane
Gas the manifold pressure is 10").
we
Read the electrical connection
details below.
Plug the range into the
wall receptacle.
PNUTEGTIINE] Before servicing, disconnect electrical
supply at circuit breaker, fuse or Power Cord.
PATI]
PLEASE READ CAREFULLY!
For
personal safety, this product must be properly grounded.