BMP 02- _ P _ _ _ _ _ A- _ _ _ _ - _ _ -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
5
Installation and connection (continued)
Direct and inverse installation
The BMP can be installed directly (active area points to the
mounting surface) or inversely.
N S
Fig. 5-12:
Example: Installation with free position magnet (inverse
installation), axially polarized position magnet (N and S can
also be reversed)
For inverse installation, a recess must be
provided for the button and the status LEDs
(dimensions, see Fig. 5-13). Otherwise, the
BMP can only be configured via IO-Link.
Mounting example with position magnet
BAM TG-MP-028 – axially polarized
0.7
BMP
18
Fig. 5-13:
Distances with position magnet BAM TG-MP-028 – axially
polarized (front view)
www.balluff.com
Mounting example with position magnet
BAM TG-XE-042 – radially polarized
Fig. 5-14:
Position magnet
0.7
BMP
BMP
Position magnet
18
Distances with position magnet BAM TG-XE-042 – radially
polarized (front view)
english
15