BMP 02- _ P _ _ _ _ _ A- _ _ _ _ - _ _ -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
7
Analog interface. Switching output and button
The analog output is deactivated with active
IO-Link communication.
The minimum measurement range is 5 mm.
During start-up the sensor is in SIO mode. After
a restart (Power Cycle) or fallback command the
sensor returns to SIO mode.
7.1
Voltage output 0...10 V
Availability depending on the selected sensor type (see
Type code on page 27).
Range Teach
Minimum
10,5 V
10 V
0 V
–2 mm
Fig. 7-1:
Analog voltage output
Setting process, see Section 7.3 on page 20.
7.2
Switching output
Switching signal (NO contact/NC contact)
The behavior can be changed using buttons or via IO-Link.
Active
Inactive
Fig. 7-2:
Switching signal
Active
Inactive
Fig. 7-3:
Switching signal with inverted output
www.balluff.com
Range Teach
Maximum
Before
After
+24 mm
Position of the magnet
Taught-in switching signal
Teach 1 (switch-on point) and Teach 2 (switch-off point)
performed
Teach 2
Teach 1
Active
Inactive
Teach-in in the entire,
set measurement range possible
Fig. 7-4:
Taught-in switching signal (example of NO contact)
Teach 2
Teach 1
Active
Inactive
Teach-in in the entire,
set measurement range possible
Fig. 7-5:
Taught-in switching signal (example of NC contact)
Setting process, see Section 7.3 on page 20.
english
19