Installation and User Manual Vienna D
2.6. If the sauna heater will not heat up
If the sauna heater will not heat up, please check that:
-
the power is on;
-
the main fuses of the sauna heater are intact;
-
is there any error messages on the control panel. In case of an error message on the control panel,
please refer to the control panel instructions.
THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES
FOR THE FUTURE USER.
2.7. Preparing for sauna heater installation
Check the following before installing the sauna heater.
- The ratio of the heater's input (kW) and the sauna room's volume (m
Table 1 on page 8. The minimum and maximum volumes must not be exceeded.
- The sauna room height must be a min. of 1900 mm.
- Uninsulated and masonry stone walls extend the preheating time. Each square metre of plastered ceiling or wall
3
surface adds 1.2 m
to the sauna room's volume.
- Check page 8 Table 2 for a suitable fuse size (A) and the correct diameter of the power supply cable (mm²) for the
sauna heater in question.
- Conform to the specified safe clearance around the sauna heater. Please refer to page 8.
- There should be enough room around the sauna heater controls for maintenance purposes. Also a doorway can
be considered as a maintenance area.
2.8. Installation
Follow the safety clearance specifications on page 8. when installing the sauna heater. Thin panel is not a suitable
mounting base. The mounting base must be reinforced with timber behind the panel. The minimum clearances
specified on page 8 table 1 must be followed also in case the sauna room wall materials are incombustible.
Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they may
cause a fire hazard.
A single sauna heater is allowed per a sauna room.