Descargar Imprimir esta página

AL-KO HW 4000 Traducción Del Manual Original De Instrucciones página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
Operation
5.2
Fill the pump
IMPORTANT! Danger of damage to the
pump! Dry running will destroy the pump!
The pump must be filled with water up to the
overflow before each use so that it can draw
water immediately.
NOTE Fill the suction hose with water before
screwing in place to reduce the suction time.
1. Open filling screw (3) using filter wrench (19/
A).
2. Pour in water through the filling screw until
pump housing (2) is full.
3. Screw in filling screw.
5.3
Initial commissioning
During initial commissioning, the PUMP ON LED
is lit and the FLOW CONTROL LED flashes.
NOTE If no water is drawn in via the suction
line after approx. 90 seconds, the dry running
protection system switches the pump off and the
ALARM LED lights up. Check the suction line, fil-
ter bowl and all screw fittings for leaks, press the
RESET button and carry out initial commissioning
again.
6 OPERATION
6.1
Switching the pump on
1. Open a shut-off device (valve, spray nozzle,
water cock) in pressure line (11).
2. Insert the plug of the mains cable into the
power socket. The pumps starts to pump.
3. Close the shut-off device in the pressure line
when there are no more air bubbles in the es-
caping water.
The pump switches off automatically after
building up the pressure and reaching the
switch-off pressure.
The pump is ready for operation.
The LED displays are off.
7.1
Normal mode
Switching condition
Pump switches on and
starts to draw water.
Pump fills the tank with
outlet closed.
467776_h
LED display
Function / action
PUMP ON LED
Commissioning: Pump filled with water, suction and
lights up. FLOW
pressure side connected, water present on the suc-
CONTROL LED
tion side. Pump connected to mains.
flashes.
If water is being fed, just the LED display
PUMP ON lights up.
6.2
Switching the pump off
1. Remove the mains plug from the plug socket.
2. Close all the shut-off devices in the pressure
line.
CAUTION! Danger of injury from hot wa-
ter After extended use against the closed pres-
sure side (> 10 min.), the water in the pump can
become very hot and may escape uncontrolled!
Disconnect the pump from the mains supply
and allow the pump and water to cool down.
Put the pump into operation again only after
all the faults have been remedied!
The risk of injury from hot water can arise in the
event of:
Incorrect installation,
Closed pressure side,
Lack of water in the suction line, or
Defective pressure switch.
Procedure
1. Disconnect the pump from the mains supply
and allow the pump and water to cool down.
2. Check the pump, installation and water level.
3. Put the pump into operation again only after
all the faults have been remedied!
7 LED DISPLAYS