If the surface becomes dirty, wipe it with a damp cloth.
-
The ventilation part of the cooker should be cleaned with a toothbrush or cotton wool.
-
If the cooker needs repairs, these should only be carried out by certified personnel, in this
case the official Cecotec Technical Support Service.
5. TROUBLESHOOTING
Error codes
When the induction cooker stops working, it shows an error code on the display referring to
a specific problem. In the following table you can find all codes, as well as their causes and
solutions:
Error
Cause
code
E0
The induction cooker is not
connected, or you are using an
incompatible cooker
E1
The IGBT sensor is open, or a
short circuit has occurred
E2
Internal overheating
E3 / E4
270 V overvoltage
90 V undervoltage
E5
Top plate sensor open / short
circuit
E6
Surface overheating
6. TECHNICAL SPECIFICATIONS
Product reference: 02855
Product: Full Magma Grill
Rated power: 2000 W
Voltage: 220 - 240 V
Frequency: 50 - 60 Hz
Solutions
Place suitable cookware on the induction
cooker.
Please contact the official Cecotec Technical
Support Service for repair.
First detect whether the air outlet is blocked
or not, and check if the induction cooker works
properly again after cooling down.
Check and make sure that the appliance is
connected to a correctly installed socket with
220-240 V ~ 50/60 Hz.
Please contact the official Cecotec Technical
Support Service for repair.
Disconnect the plug from the socket and wait
until the appliance has cooled down.