Installation
How to Install the Unit
1. To prevent vibration and noise, make sure
the unit is installed securely and firmly
2. Install the unit where the sunlight does not
shine directly on the unit.
3. The outside of the cabinet must extend
outward for at least 12" (30.5 cm) and
there should be no obstacles, such as a
fence or wall, within 20" (50.8 cm) from the
back of the cabinet because it will prevent
heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the
structure.
4. Install the unit a little slanted so the back is slightly lower than the front
(about
1
/
"(12.7 mm)).
2
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 30"~60"(76.2~152.4 cm) above the floor level.
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
This unit is designed for installation in standard
double hung windows with actual opening widths
from 27" to 39" (68.6~99.1 cm).
The top and bottom window sash must open
sufficiently to allow a clear vertical opening of
16" (40.6 cm) from the bottom of the upper sash
to the window stool.
Cooled air
27" to 39"
(68.6~99.1 cm)
16" min (40.6 cm)
(With frame curtain)
Interior wall
5
23
/
" min.(60 cm)
8
(Without frame curtain)
10
Fence
Awning
Heat
radiation
About
1
/
"(12.7 mm)
2
Over 20"(50.8 cm)
Stool
Offset
1
1
/
" to 1
/
2
(12.7~31.8 mm)
Sill
Exterior
"