17
DN
961588_00
english
The pump flanges are drilled with mounting holes, PN6/PN10/PN16.
For safe screwing of the flanges, the shims supplied (B)
must be fitted.
A
B
Safety elements (e.g. snap rings)
Warning
are not permissible.
For PN 10/16, special seals and screws
Warning
must be used.
Warning
Use the relevant screws
for nominal pressure PN.
PN 6
DN 40
DN 50
M 12
DN 65
DN 80
DN 100
M 16
Recommended screw tightening torque
for M 12 <40 Nm
for M 16 <95 Nm
Installation of combined flange with combined flange
is not permissible.
After installation is completed, put on the heat insulation shells
and secure with cable bands.
A
PN 10 / PN 16
PN 6
M 16
Ø 14
M 16
B
PN 10 / PN 16
Ø 18
–
–