30
Supply voltage
Motor protection
Type of protection
Winding category
Temperature category
Media temperature
Ambient temperature
Maximum operating
pressure
Noise
Leakage current
Power consumption
when pump switched off
Performance factor cos-phi
EMV
(electromagnetic
compatibility)
english
11. Technical data
1×230 V ±10%, 50/60 Hz, PE
External motor protection is not required
IP 44 (EN 60529)
Insulation category F
TF 110 (EN 60335-2-51)
+15 °C to +110 °C (ModulA RED)
+15 °C to +85 °C (Modula BLUE)
max. 40 °C
In transportation: –40 °C up to +70 °C
The maximum operating pressure is given on the nameplate:
PN 6: 6 bar
PN 10: 10 bar
PN 16: 16 bar
Sound pressure level under 43 dB(A)
The mains filter of the pump causes a leakage current
to the earth of < 3.5 during operation
<3W
The ModulA has an integrated performance factor correction filter
(PFC). This ensures that cos-phi is always between 0.98 and 0.99
and is therefore kept very close to the ideal value 1.
EN 55014-1:2006, EN 55014-2:1997, EN 61000-3-3:2008 and
EN 61000-3-2:2006
12. Disposal
This ModulA circulation pump was developed with sustainability
in mind. This also includes waste prevention and recyclability
of materials.
This product as well as its parts must be disposed of according
to the local regulations.