Descargar Imprimir esta página

DeWalt DXCMTA6590412 Manual De Instrucciones página 14

Gas de compresor portátil

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Turn regulator knob (F) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 psi.
4. Remove hose and accessory.
5. Drain the air tank. See Draining Air Tank under Maintenance.
NOTICE: Risk of property damage. Place engine fuel valve lever
(M) in the OFF position before moving or transporting unit.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
6. Allow the compressor to cool down.
7. Wipe air compressor clean and store in a safe, non freezing area.
MAINTENANCE
WARNING:The following procedures must be followed when
maintenance or service is performed on the air compressor.
1. Ensure engine ON/OFF switch (C) is in the OFF position.
2. Disconnect spark plug wire.
3. Drain air tank.
4. Allow air compressor to cool down before starting service
NOTE: All compressed air systems contain maintenance parts (e.g.
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of
in accordance with local, state, and federal laws and regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should
be performed by a D
WALT factory service center or a D
e
authorized service center.
Maintenance Chart
Procedure
Check safety valve
Inspect air filter
Drain air tank
Oil leak inspection
Check for unusual noise/vibration
Check for air leaks
Clean compressor exterior
Remove tank from service
Engine
*
To check for air leaks apply a solution of soapy water around
joints. While compressor is pumping to pressure and after
pressure cuts out, look for air bubbles to form.
+
Perform more frequent in dusty or humid conditions.
++ For more information, call 1-888-895-4549
Checking Safety Valve (Fig. 1)
WARNING: Hot surfaces. Risk of burn. Pump head, and
surrounding parts are very hot, do not touch (see the Hot
Surfaces identified in Fig. 2). Allow compressor to cool prior
WALT
e
to servicing.
WARNING: Risk of bursting. If the safety valve does not work
properly, over-pressurization may occur, causing air tank rupture
or an explosion.
WARNING: Risk from flying objects. Always wear certified safety
14
X
X +
X
X
X
X*
X
++
X
See engine instruction manual.

Publicidad