BEFOREYOU BEGIN
Read these instructions completelg
and carefullg.
• IMPORTANT - Save these
instructions
forlocal i nspector's
use.
"
IMPORTANT
-Observe oli governing codes
and ordinances.
• Note to Installer
- Be sureto leave theseinstructions
withtheConsumer.
• Note to Consumer - Keep theseinstructions
for future reference.
• Skill level- Installation of this appliance requires basic
mechanical skills.
• Completion time - Approximotelg 1 hour
• We recommend that two people install this product.
• Proper installation is the responsibilitg of the installer.
• Product failure due to improper installation
is not covered under the Worrontg.
(_
ELECTRICAL REQUIREMENTS
-AWARNING! Risk o felectric s hock, can
cause injury
or death. This appliance
must be
properly
grounded.
Where a 2-prong
wall outlet
is encountered,
it is your responsibility
and
obligation
to have it replaced
with o properlg
grounded
3-prong
outlet.
Some models require a 115/120-volt o.c.,
60-Hz grounded outlet protected with a
1S-amp time delag fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibilitg of
electric shock hazard. If the wall outlet gou plan to use is
onlg o 2-prong outlet, it is gour responsibilitg to have it
replaced with o properlg grounded 3-prong wall outlet.
Do not, under ong circumstances,
cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum
house wiring meg present special
problems-consult
a qualified
electrician.
ELECTRICALREQUIREMENTS(cont.)
Some models require 230/208-volt o.c.,protected
with Utime delog fuse or circuit breaker.These
models should be installed on their own single
brunch circuit for best performance and to prevent
overloading house or apartment wiring circuits,
which could cause o possible fire hazard from
overheating wires.
IMPORTANT!
GEstronglg recommends the removal of the old wall case
and the installation of a new GE Wall Case,If gou decide to
keep the existing wall case, gou meg need a kit to ensure
proper performance. If gou DO NOT use o kit, gou run the
risk of poor performance or product failure, This is not
covered under the terms of the GEworrontg.
J-MODEL QUALIFYING QUESTIONS
J-model air conditioners mog fit in existing wall cases.
However,theg often need u kit to properlg adopt the case
to the GEair conditioner.Answer these questions and see
the chert on the next page for the proper kit.
r_
What brand air conditioner will gou be replacing?
r_ .What are the dimensions of the wall case currentlg
m use?
r_ Whet is the model number of the chassis
currentlg in use?What is the model Ior Tgpe} number
of the wall case currentlg in use?
Frequentlg,the J-model adopter kit will opplg to another
brand model "series"or specific vintage. In these cases,
gou need the chassis model number and/or the wall
case or "tgpe" number to confirm the use of the correct
adopter kit.
r_ What tgpe of outdoor grille is used with the current
wall case?
There may be on architectural grille attached to o wall
case to enhance the exterior appearance of the building.
Custom grilles may be used with J-model wall cases
provided o J-model adopter kit is also used to ensure
proper airflow.