Performance
Data Sheet
SmartWater
Filtration Sgstem
GSWF Cartridge
This sgstem has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the sgstem, as specified in NSF/ANSI 42/5&*
(!00% safetg factors built in for unmetered usage)
Parameter
Chlorine
T&O
Particulate**
USEPA
MCL
Influent
Average
1.845 mg/L
143,333 #/mL
Standard
No. 42: Aesthetic
Effects
Influent
Challenge
Effluent
Concentration
Average
Maximum
2.0 mg/L+10%
< 0.05 mg/L
0.05 mg/L
at least 10,000 particles/mL
29.83 #/mL
140 #/mL
% Reduction
Average
Minimum
> 97.29%
96.43%
99.98%
99.91%
Min. Required
Reduction
> 50%
>85%
Parameter
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
USEPA
MCL
1 NTU***
99.95%
Reduction
0.015 mg/L
0.015 mg/L
0.0002 mg/L
0.003 mg/L
Influent
Average
10.3 NTU***
200,000 #/L
0.15 mg/L
0.14 mg/L
0.0216 mg/L
0.008 mg/L
Standard
No. 53: Health
Effects
Influent Challenge
Concentration
1+1 NTU***
Hinimum 50,000 L
0.15 mg/L+lO%
0.15 mg/L+lO%
0.002 mg/L+lO%
0.009 mg/L+lO%
Effluent
Average
0.106 NTU
0
< 0.001 mg/L
0.001 mg/L
< 0.00002 mg/L
< 0.002 mg/L
Maximum
0.14 NTU
0
< 0.001 mg/L
0.003 mg/L
< 0.00002 mg/L
< 0.002 mg/L
% Reduction
Average
Minimum
98.97%
98.61%
> 99.99%
> 99.99%
> 99.33%
> 99.33%
> 99.29%
97.86%
99.07%
98.75%
> 76.12%
> 66.67%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 +_0.5; temp. of 60 ° +_5°F (20° +_3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbiditg units
Operating
Specifications
[] Capacitg: certified for up to 750 gallons (2,838 I);up to six months
[] Pressure requirement:/40-120 psi (2.8-8.2 bar)
[] Temperature: 33-100°F (0.6-58°C)
[] Flow rate: 0.5 gpm (1.9 Ipm)
General
Installation/Operation/Naintenance
Requirements
[] Flush new cartridge at full flow for 5 minutes to purge out trapped air.
[] Replace cartridge when flow becomes too slow.
Special
Notices
[] Installation instructions, parts and service availabilitg, and standard warrantg are included with the product when shipped.
[] This drinking water sgstem must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
[] Do not use with water that is microbiologicallg unsafe or of unknown qualitg without adequate disinfection before or after
the sgstem. Sgstems certified for cgst reduction mag be used on disinfected water that mag contain filterable cgsts.
[] The contaminants or other substances removed or reduced bg this water treatment sgstem are not necessarilg in gour water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard laboratorg conditions, actual performance mag varg. Sgstems
must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
System tested and certified by NSF International against Standard 42 for the reduction of
chlorine, taste and odor, particulate Class I and Standard 53 for the reduction of cyst, lead,
Lindane, Atrazine and turbidity.
Hanufactured for: General Electric Company, Louisville, KY40225