4.2 - Disabling the safety devices
EDGE
The control unit provides (default setting) for the installation of a safety edge connected to the EDGE/EDGE inputs; in the event of a missing or
incorrect connection, the operation of the automation is inhibited. In a system where a safety edge is not to be installed, its use can be disabled
by setting the EDGE dip-switch to ON.
!
WARNING
confirm the safety edge deactivation by pressing and holding the buttons
PHOTO 2
The control unit provides (default setting) for the installation of one or more photocells connected to the PH2 input, in the event of a missing
or incorrect connection, the operation of the automation is inhibited. In a system where a PH2 is not to be installed, its use can be disabled by
setting the PH2 dip-switch to ON.
!
WARNING
confirm the PH2 deactivation by pressing and holding the buttons
PHOTO 1
The control unit provides (default setting) for the installation of one or more photocells connected to the PH1 input, in the event of a missing or
incorrect connection, the operation of the automation is inhibited. In a system where a PH1 is not to be installed, its use can be disabled by setting
the PH1 dip-switch to ON.
!
WARNING
confirm PH1 input deactivation by pressing the
stops flashing.
4.3 - Display during normal operation
When first switched on, the control unit shows a scrolling text on
the display indicating: board model, firmware version and serial
number and as last information
it is necessary to select the type of motor to begin configuring the
system. To select the type of motor, scroll the list with the UP
and DOWN-RADIO
buttons;
MESSAGE
MEANING
The door travel has not been learned; perform the auto-learning procedure
Gate closed, control panel restarted
The gate is opening
The gate is closing
The gate was stopped during the opening manoeuvre
The gate was stopped during the closing manoeuvre
PH1 intervention (photocell 1)
PH2 intervention (photocell 2)
The automation is performing the realignment procedure
Gate open, automatic closing timer not active
The gate is performing a partial opening
The gate is stopped in the partially open position
The gate has reached the open position and automatic re-closing is active; the flashing dash indicates that the
countdown is active. During the last ten seconds, the seconds remaining until reclosing are indicated
The gate has been opened with the PAR command and the automatic re-closing timer from partial opening is
active; during the last ten seconds, the seconds remaining until re-closing are indicated
Auto-learning procedure blocked due to safety intervention or intentional stop
Auto-learning of leaf 1 opening travel
Auto-learning of leaf 2 opening travel
Auto-learning of leaf 1 closing travel
Auto-learning of leaf 2 closing travel
Personalised learning of the slowdown point during leaf 1 opening
Personalised learning of the slowdown point during leaf 2 opening
Personalised learning of the slowdown point during leaf 1 closing
Personalised learning of the slowdown point during leaf 2 closing
and
buttons simultaneously and holding them down until the PH1 led
at the motor concerned, press and hold down the MENU button
until DONE appears on the display.
to indicate that
WARNING
shows the correspondence between the motor model and the numbers on
the display. The following table shows the messages displayed during
normal operation of the automation:
and
until the EDGE LED stops flashing.
and
until the PH2 LED stops flashing.
!
The ADVANCED PARAMETERS (paragraph 5.2) table
EN
9