Adjusting the suction power:
 Set auxiliary air slide on the handle tube.
Switching off the vacuum cleaner:
 Set switch to position >0<. Vacuum cleaner is switched off.
 After switching off, pull the mains plug out.
 Roll up mains connection cable.
 Store the mains connection cable on the cable hook.
 Store the suction tube by inserting it into the accessories holder on the container rear wall.
 Put the suction hose ends together so that no dirt particles leak out.
 Remove Power tool.
3.4
Operating modes
Sucking up dry materials:
 Only use a dry filter, vacuum cleaner and accessories, so that the dust does not stick and or
cake.
 When vacuuming soot, cement, plaster or similar dusts: Insert a PE disposal bag in the dirt
container.
 Always use disposal bags in combination with folded filter cartridges.
Note: M class vacuum cleaners should be preferably used as vacuum cleaners for dry dusts.
Sucking up liquids:
Electrical shock hazard! If any foam or liquid is discharged, immediately switch off the
vacuum cleaner. Empty dirt container and folded filter cartridge!
Note: Regularly clean the water level sensors (1) and inspect for signs of
damage
 Vacuum cleaning without fleece filter bags.
The folded filter cartridge designed for wet vacuum cleaning.
The built-in sensor switches the motor off when the container is full. The handling of the vacuum
cleaner can be compromised by a full container.
 Empty container (see Emptying the container).
Note: If the vacuum cleaner is not switched off, the re-start protection remains effective. The
vacuum cleaner is ready for operation only after the unit has been switched off and switched on
again.
 Remove the suction hose from the liquid before emptying.
 After switching off, a small quantity of water can flow back out of the hose, as a result of the
high suction level and the favourable flow condition in the container.
 After wet vacuum cleaning insert dry filters for picking up dry dust.
Note: When changing frequently between dry and wet vacuum cleaning, use a second set of fil-
ters, preferably polyester folded filter cartridges.
3.5
Permanent filter cleaning
The vacuum cleaner is fitted with an electromagnetic filter cleaning system, which can be used
to clean any attached dust from the filter cartridges.
Filter cleaning is performed automatically during the next working break when the minimum vol-
ume flow level is reached (switch setting >RA<).
3.6
Emptying the container
Note: Only permitted for dust with workplace exposure limits > 1mg/m
 Switch off the vacuum cleaner, pull out the mains plug.
 Open the latches.