Electrical data • Caracteristicas eléctricas
Charactéristiques electrique • Dados eléctricos
Max. power input
absorbida y fusible recomendado
Consommation maximale
Potência máx. absorvida
Supply voltage (see type plate)
Tensión de entrada (ver etiqueta identificativa)
Alimentation électrique (voir plaque sign.)
Tensão de rede (ver placa indicadora)
Recommanded cable jacket diameter
Diámetro exterior del cable recomendado
diamètre recommandé pour la gaine du câble
Diâmetro recomendado do invólucro de cabo
Cable cross-section and fuse protection
Sección de cable y fusible
Section des fils et fusibles
Secção do cabo e fusível recomendado
Contact loading
Carga del contacto
Pouvoir de coupure
Carga de contato
Maintenance • Mantenimiento • Entretien • Manutenção
230/115/24/...
24 Vdc
Vac
P < ,0 VA
P < ,0 W
Uac = ... ±10%
U
= 4Vdc
0
-0/+5%
50 – 60 Hz
ø 5,8 - 8,5 mm
3 x 0,75 mm² / 5 x 0,5 mm²
0,5 A *)
00 mA *) **)
<50Vac/<0,5A
>Vdc/>50mA
english
potential-free contact
The alarm signal can be relayed via a
potential-free contact. The changeover
contact can be operated, e.g., in the fail-
safe mode.
When operating voltage is being applied
and the BEKOMAT device is functioning
correctly, the alarm relay is energized.
The contact element (0.7 - 0.8).
When there is no operating voltage or
in the case of a fault signal, the alarm
relay drops out. The contact element is
open (alarm).
Externeral test button (optional)
Here, the normal test button function
has been extended for additional use
outside the BEKOMAT unit. This makes
it possible to discharge any condensate
in the unit by remote control, if required.
When the external contact closes, the
valve will open.
*) time lag
**) min. internal resistance of
voltage source Ri > 12 Ohm
Maintenance recommendation:
• Housing and valve should be cleaned
once a year.
• Replace wearing parts once a year.
Set of wearing parts ( x )
ECO-DRAIN 13
ECO-DRAIN 13 CO
ECO-DRAIN 13 CO PN25
AN84540000
Functional test of ECO-DRAIN device:
• Briefly press test button 2 sec.
• Valve opens for condensate dis-
charge.
Checking of alarm signal:
• Shut off condensate inflow.
• Press test button for at least minute.
• Red LED flashes (after 1 minute).
• Alarm signal is being relayed.
ECO-DRAIN 13, 13 CO, 13 CO PN25
AN824540
AN824540