Installation • Instalación
Installation • Instalação
wrong • no correcto
incorrect • incorrecto
8
correct • correcto
correct • correcto
english
Note:
minimum height of installation
The inflow point must be located lower
than the lowest point of the collecting
tank or vessel.
Note:
continuous slope
The feed line must always be laid with a
continuous downward slope. If the space
for installation is too restricted, the lower
feed line must be provided with a sepa-
rate venting line.
Note:
Venting line
In the case of large condensate quanti-
ties, it will always be necessary to install
a separate venting line.
Note:
continuous slope
It is important to avoid water pockets
when using a pressure hose as a feed
line!
Note:
continuous slope
Water pockets must also be avoided
when laying a feed pipe.
ECO-DRAIN 13, 13 CO, 13 CO PN25