Technical data
6.1
Accuracy
The specifications are typical values for the BTL6-P510...
at 24 V DC and room temperature, with a nominal length
of 500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
Typical
Sampling rate with
Nominal length ≤ 1300 mm
Nominal length > 1300 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
1)
6.2
Ambient conditions
Ambient temperature
Storage temperature
Humidity
Rod pressure rating (when
installed in hydraulic cylinders)
For Ø 8 mm
For Ø 10.2 mm
Shock rating
Continuous shock
per EN 60068-2-27
3)
Vibration
per EN 60068-2-6
3)
Degree of protection
per IEC 60529
KA/LA
6.3
Control signals
INIT impulse
Level
Pulse widths
Reverse polarity protection
4)
START/STOP impulse
Pulse widths
www.balluff.com
±10 µm
1 kHz
0.5 kHz
≤ ±200 µm
≤ ±0.04 % FS
Typ. ±0.02 % FS
Typ. 25 µm/K
2)
–40°C...+85°C
–40°C...+100°C
< 90%, non-condensing
≤ 250 bar
≤ 350 bar
100 g/6 ms
50 g/2 ms
12 g, 10...2000 Hz
IP67
+5 V RS 485/422 driver
1...3 µs
1.5 * U
B
5...7 µs
6.4
Supply voltage (external)
Voltage, stabilized
4)
Ripple
Current draw (at 24 V DC)
Inrush current
Typical power consumption
Reverse polarity protection
Overvoltage protection
Dielectric strength (GND to
housing)
6.5
Dimensions, weights
Rod diameter
Nominal length
For Ø 8 mm
For Ø 10.2 mm
Weight (depends on length)
Housing material
Cover material
Rod material
Rod wall thickness
For Ø 8 mm
For Ø 10.2 mm
Fitting method
BTL6-...-KA_ _
Cable material
Cable temperature with fixed
routing
Cable diameter
Permissible bending radius
Fixed routing
Moved
Nominal length = 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
2)
sea level.
Individual specifications as per Balluff factory standard, resonant
3)
frequencies excluded
For
: The BTL must be externally connected via a limited-energy
4)
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
10...30 V DC
≤ 0.2 V
ss
≤ 50 mA
≤ 2.5 A
1.2 W
Up to 40 V
Up to 36 V
500 V DC
8 mm or 10.2 mm
50...1016 mm
50...2000 mm
Approx. 2 kg/m
Stainless steel
Stainless steel
Stainless steel
0.9 mm
2 mm
Mounting flange
PUR;
cULus 20549
80 C, 300 V,
internal wiring
–40°C...+90°C
Max. 6.7 mm
≥ 32 mm
≥ 95 mm
english
11

Publicidad

loading