SELECTING THE CORRECT
SELECTING THE CORRECT
JET PUMP SYSTEM
JET PUMP SYSTEM
It is important to determine which jet pump system you
need. A jet pump is a centrifugal pump with a jet
(ejector) assembly. Red Jacket Water Products sells three
types of jet pumps:
Shallow Well Jet Pumps with built-in jet assemblies for
maximum lift of 25'. See Fig. 1
Convertible Jet Pumps can be used for Shallow wells (to
25'), with a bolt on shallow well adapter; or deep well
(over 25') applications with a jet assembly in the well.
See Fig. 1 and 2.
Deep Well Jets should only be used on deep well (over
25') applications with the appropriate jet assembly.
See Fig. 2 and 3
Typical Red Jacket Water Products Jet Pump Installations
Typical Red Jacket Water Products Jet Pump Installations
SHALLOW WELL
SYSTEM
Dedicated Shallow Well
Model
SRJ
Convertible with
Shallow Well Adapter
DRJ
Requires:
• Pump
• Tank
Shallow Well Adapter (SW--)
required
SRJ has a built-in jet assembly
(shallow well adapter)
2
DOUBLE (TWIN) PIPE
DEEP WELL SYSTEM
Model
Requires:
• Pump
• Tank
• Double (Twin) Pipe
Jet Assembly
• Pressure
Control Valve
Fig. 1
Use a shallow well pump or a convertible pump with a
Shallow Well Adapter for wells with a maximum suction
lift of 25'. This 25' includes actual vertical lift plus
friction loss in the suction piping. Shallow well systems
are identified by one (1) pipe going to the well, lake or
river. They are good for city water booster systems and
pumping from cisterns or tanks. See Typical Installations,
Figs. 1, 4 and 5.
Deep well jet pumps are used for lifts greater than 25'
and must have two pipes going to the well. There are two
types of deep well jet assemblies, double (twin) pipe and
single pipe (packer) systems.
Consult with your Professional Dealer or Distributor to
select the best pump system for your application.
• Liquid temperature must not exceed 140° F (60°C).
• Protect unit from freezing
2" SINGLE PIPE (PACKER)
DRJ
Requires:
• Pump
• Tank
• Single Pipe (Packer)
• Single Pipe (Packer)
• Pressure
Fig. 2
DEEP WELL SYSTEM
Model
DRJ
Adapter (for well
head)
Jet Assembly
Control Valve
Fig. 3