Power the Motor
The electrical supply must be a separate branch
DANGER
circuit with a properly sized breaker or fuses.
All wiring must conform to National (NEC),
CSA, state, provincial, and local codes. Power
supply voltage, phase and controls must match
Hazardous voltage
can shock, burn or
motor.
cause death.
NEVER RUN A PUMP DRY, DAMAGE WILL
RESULT, AND THE WARRANTY WILL BE VOIDED!
ALWAYS DISCONNECT AND LOCK-OUT
DANGER
ALL ELECTRICAL POWER WHEN
INSTALLING OR WORKING ON PUMPS,
MOTORS, OR SWITCHES. INSURE THE
POWER SUPPLY BREAKER IS OFF OR THE
Hazardous voltage
can shock, burn or
cause death.
DISCONNECT (WHERE USED) IS OFF.
Remove the pressure switch cover. Attach the power
supply wires, either 115 or 230 depending on the motor
voltage, to the Line terminals of the pressure switch.
BOOSTER SYSTEMS
BOOSTER SYSTEMS
Use the basic instructions for either a Shallow Well or Convertible with Shallow Well Adapter. If a city water booster
system please plumb per Fig. 4. If pumping from a cistern or water tank plumb per Fig. 5.
SRJ OR DRJ SERIES
UNION
Use flow
control
or ball
valve on
suction to
BALL
throttle
VALVE
GAUGE
pump. Must
UNION
be sized, or
set, to load
motor below
UNION
max.
nameplate
amps.
PRESSURE
SEASONAL SERVICE
SEASONAL SERVICE
It is necessary to drain the entire system where the pump,
tank, and piping will be subjected to freezing. Horizontal
pumps may have two drain plugs, one on the casing (part
where pipes attach) and another on the motor adapter.
They are also located near the bottom of the pump.
6
WATER MAIN
CHECK
VALVE
GATE
TO SIZE TANK
VALVE
PROPERLY –
MATCH
DRAWDOWN
OF TANK TO
CAPACITY
OF PUMP.
RELIEF
VALVE
SWITCH
Fig. 4
Attach the green or bare ground wire to either green
ground screw in the switch. It makes no difference which
Line terminal you attach the hot- L1 (usually Black) and
neutral- N (usually white) 115 volt wires to on the
switch. The same goes for a 230 volt hook-up, either
wire can go on either Line terminal. Re-install the switch
cover. NOTE: Motor voltage is NOT changed in the
pressure switch.
Check to insure that the motor is wired to match the
incoming voltage. All motors have a sticker near the
pressure switch that identifies the pre-wired voltage. All
1
hp jet pumps are factory wired for 115 V, and
2
and larger are wired for 230V. The motor voltage must
be changed inside the motor cover, not in the pressure
switch. Make sure the breaker or disconnect is OFF
before entering the motor cover. All motors have a
wiring diagram on the cover label and it is also found in
this manual. See Motor Data in Technical Data.
MAIN POWER BOX
GATE
VALVE
FUSE BOX
STORAGE TANK
OR
SWITCH
GATE
HYDRO-
VALVE
JET PUMP
TANK
CHECK
VALVE
Fig. 5
3
hp
4
PRO