Panadero P65 Manual De Instalación Y Mantenimiento página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.19. Check the space between the stove, the fuel, and any flammable material, check drawing 3.
4.20. Do not install the stove in a sleeping room.
4.21. The power cable provided by PANADERO is 1.4m long; you might need a longer one. Always use a cable with
ground plug.
FREE SPACES AND MINIMUM DISTANCES WITH FLAMMABLE MATERIAL.
Security distances should be respected when the stove is installed in spaces where materials, either
construction materials or those surrounding the stove, are likely to be flammable.
4.22. If the floor is made of a combustible material, install a fire protection between the floor and the stove.
A
Lateral wall.
Back
of
the
B
separation that allows visualizing the
label marking the stove.
C
1.5 x depth of stove.
D
Shelf.
E
Depth of stove.
Although we cannot keep track of or describe every single installation, option, or the local installation
regulations corresponding to your area, PANADERO guarantees that the installations suggested below will enable
your stove to function properly, and to conform to minimum personal and material safety measures.
If you are installing your stove in a building, in addition to respect local regulations on gas flues, you should
consult with the residents' association to avoid future problems.
Please read the entire manual carefully, especially the chapter on installation to ensure your stove
operates properly and at full power.
4.23. The installation shown below is the most common. Please bear in mind that if the gas flue pipe located on
the outside of the dwelling is in an area where people pass by, insulated tube must be used.
LOCATION AND SAFETY DISTANCES.
stove.
Minimum
≥ 80 mm
See dimensions
≥ 400 mm
See dimensions
EXAMPLES OF FLUE INSTALLATIONS.
≥ E
25
Drawing 3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

P70P90

Tabla de contenido