Installation requirements
Special gas requirements (gas models sold in Massachusetts)
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
•
-
Gas leaks may not be detected by smell alone.
-
Gas suppliers recommend you purchase and install a UL-approved
gas detector. Gas detector should be installed in accordance with the
manufacturers instructions.
•
Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
•
A T-handle manual gas valve MUST be installed in the gas supply line to your
range.
•
If a flexible gas connector is used to install your range, multiple flexible gas
lines must not be connected in series.
16 English
Install_DOP36T86DLS_DG68-01106G-00_EN+MES+CFR.indb 16
Install_DOP36T86DLS_DG68-01106G-00_EN+MES+CFR.indb 16
Electrical requirements
WARNING
To reduce the risk of fire, electric shock, or personal injury:
All ranges
•
Do not use an extension cord or adapter plug with this range.
This range must be properly grounded.
•
•
Check with a qualified electrician if you are in doubt as to whether your range
is properly grounded.
•
Do not modify the plug provided with your range—if it doesn't fit the outlet,
have a proper outlet installed by a qualified electrician.
•
All wiring and grounding must be done in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFPA No.
70 – Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 –
Latest Revisions and local codes and ordinances.
•
Wiring diagram is located on the back of the range. (Inside of the cover back
wire)
•
This range is equipped with an electronic ignition system that will not operate
if plugged into an outlet that is not properly polarized.
Dual fuel models
•
Canada models are equipped with a power cord with an equipment-grounding
conductor and a grounding plug.
(The power cord is not provided in US model.)
•
A 240-Volt, 60-Hz, AC, approved electrical service with 40-amp circuit breaker
or time-delay fuse is required for all U.S. and Canadian models.
•
Check for ¾-in (1.9-cm) UL-listed strain relief where the power cord comes out
of the range cabinet.
•
Do not reuse a power supply cord from an old range or other appliance.
•
The power cord electric supply wiring must be retained at the range cabinet
with a suitable UL-listed strain relief.
•
A time-delay fuse or circuit breaker is also recommended.
2023-02-28 오전 10:19:02
2023-02-28 오전 10:19:02