5.7. CAPACITANCE MEASUREMENT
Before carrying out capacitance measurements on circuits or capacitors, cut
off power supply from the circuit being tested and let all capacitance in it be
discharged.
Fig. 9: Use of the instrument for capacitance measurement
1. Select the position
2. Press the MODE key until the symbol "nF" is displayed.
3. Insert the red cable into input terminal VHz%
terminal COM
4. Position the test leads in the desired points of the circuit to be measured (see Fig. 9).
The display shows the value of capacitance.
5. If the symbol "O.L" is displayed, this indicates overload status.
6. For use the HOLD and RANGE functions, please refer to § 4.2.
CAUTION
EN – 14
and the black cable into input